With the continuous development of technology, the current commercial lighting products from the first generation of incandescent lamps; the second generation of fluorescent lamps, halogen lamps; the third generation of high-intensity gas discharge lamps and the current mainstream fourth-generation LEDs (led). The lighting efficiency of lighting fixtures is getting higher and higher, and it has been developing towards energy saving and environmental protection. However, it is undeniable that the development of electric light sources has brought many new problems. In addition to the impact on the environment and energy, the impact of artificial lighting environment on human health cannot be ignored. Nowadays, people not only pay attention to the physical performance effects of lighting, but also pay attention to the photobiosafety of lighting. At present, most of the commercial electric light source lighting products are driven by AC. The influence of the stroboscopic effect of the lamps on human health has become a key problem for various lighting products.
The reading and writing work table lamp is an enhanced lighting for people's daily study, work and computer work. Due to the long time of use, it has become one of the lighting products most in contact with human daily activities. Moreover, the population used also includes a large number of adolescents in puberty. The stroboscopic effect of reading and writing desk lamps is also an important factor in inducing myopia in young people. Therefore, in recent years, there has been a "no stroboscopic" protection. Eye table lamp." Since the 'eye protection table lamp' has not undergone rigorous scientific argumentation and impartial third-party testing, and the method of rotating gyro used to verify stroboscopic on the market is very rough and cannot obtain accurate quantitative results, this kind of 'eye protection table lamp' Calling is unscientific.
To sum up, study the stroboscopic effect of reading and writing desk lamps for deep understanding of the stroboscopic mechanism, reduce the adverse effects of reading and writing table lamp illumination on the human body, and create a lighting environment that is highly environmentally friendly, safe and reliable, and beneficial to people's work and life. It has a very important meaning.
Flashing and strobe
The definition of flicker in the ninth edition of the Illumination Manual published by the North American Institute of Illumination (IESNA) is a rapid change in the intensity of the light source. For lighting products, whether it is the traditional light source or the current LED light, as long as it is driven by AC, it will produce flicker. The characterization of the degree of flicker is mainly based on the frequency of the exchange, the persistence of the light emitted by the source and the observation conditions. Blinking has a significant effect on moving objects in the observation range. Under flashing illumination, objects may appear discrete rather than continuous. This effect is called stroboscopic effect. The level of stroboscopic effect depends on the speed and amplitude of the flicker, as well as the rate at which the object moves and the state of observation.
IESNA's lighting experts have proposed the use of flicker percentage and scintillation index to characterize the stroboscopic characteristics of the illumination. The calculation of the two is shown in Figure 1.
Figure 1. Percentage of periodic waveform flicker with respect to traditional scintillation metrics = 10096x(AB)/(A+B)
The difference between the two metrics is that the percentage of flicker is only the peak-to-peak ratio; the scintillation index is a good illustration of the difference between the output waveforms, and the mathematical characterization is more accurate, but fewer people know the scintillation index and the illumination It is rare to find research in the literature, in part because the scintillation index requires complex mathematical integrals and accurate acquisition of related waveforms. In view of this, the current common stroboscopic evaluation parameter selection flicker percentage is also called the fluctuation depth. The wave depth is the ratio of the difference between the maximum value and the minimum value in one cycle to the sum of the maximum and minimum values of the light output in the periodic light output waveform, expressed as a percentage.
Regarding flicker and stroboscopic, China has not published relevant standards, and only the requirements of flicker are considered in the CQC voluntary certification technical specification "Technical Specifications for Visual Work Table Lamp Certification". The measurement method of stroboscopic is also controversial internationally. There is no unified and effective quantitative analysis method. The current concept of wave depth has been a big step in the study of stroboscopic. The US IEEE released IEEEPAR1789 "Potential Health Effects of LED Lighting Flashing (Draft)" using the depth of fluctuation to assess the stroboscopic effect.
Strobe light biohazard
The impact of light on human health is a long-term, chronic accumulation process, and developed countries in the world have started relevant research very early. According to different factors such as the flickering frequency of light and the variation range of light intensity, the degree of damage of light to the human body is also different. The results of the current study found that the stroboscopic effect causes adverse physiological responses in the human body including:
(1) Headache and eye fatigue
Dr. Wilkins et al. found that office personnel using high-frequency electronic ballast luminaires to reduce headaches by using 50 Hz magnetic ballasts to reduce headaches by a factor of two according to the National Headache Foundation report |5|: "Many migraine patients Light is very sensitive, such as bright light and flicker, which is more likely to cause migraine. Slow blinking is usually more likely to cause migraine than fast blinking." "Some fluorescent lighting or similar effects from the flicker of a television or movie screen have a similar effect."
(2) Photosensitive epilepsy
Light-sensitive people can develop epilepsy even in short-term exposure under visible light modulation in the range of 3-70HZ, which probably affects 1 in 4000 people aged 5-24 years, usually starting around puberty, and 75% of the population will be sensitive to light throughout their lives.
(3) Vision loss
Veitch and McColl discovered in 1995 that a 100-120 Hz modulated inductive ballast fluorescent lamp system would reduce the average visual acuity of a population compared to high frequency electronic ballasts. This often happens in paper reading and text reading on computer screens.
(4) Distraction of attention
The surroundings of the human eye are more sensitive to strobe, such as strobe lights or rapid modulation of the taillights that attract drivers to stare at them. Removing your eyes in advance may be dangerous for drivers or people and things driving on the road. The stroboscopic light source combined with the running machine produces an opening and closing effect, and the damage to the person can result in significantly different movement and stopping speeds. This hazard was identified in the industry ten years ago.
(5) Autism
Children with autism are particularly sensitive to changes in the environment, and stroboscopic lighting increases the recurrence of this behavior. The proportion of children with autism in the United States is about 1/110.
When the human body is exposed to the stroboscopic lighting environment, the conditions that are prone to adverse reactions are: long contact time, large area of the retina receiving stimulation, center of field of view, high brightness of the flash, high contrast with ambient brightness, and deep flash color. red.
The relationship between the fluctuation depth of the stroboscopic frequency and the frequency is shown in Fig. 2. The unaffected area in Fig. 2 is indicated by green, and the low risk area is indicated by orange. The upper limit of the low-risk area is the fluctuation depth line, which is less than 0.08 times the flicker frequency, which is equivalent to 2.5 times the unaffected edge.